Mitsubishi drive repair | Mitsubishi inverter parameters | Mitsubishi inverter price of FR-A740-7.5K-the CHT
Information Name: | Mitsubishi drive repair | Mitsubishi inverter parameters | Mitsubishi inverter price of FR-A740-7.5K-the CHT |
Published: | 2012-03-27 |
Validity: | 999 |
Specifications: | FR-A740-7.5K-the CHT |
Quantity: | 999.00 |
Price Description: | |
Detailed Product Description: | A700 product is suitable for all types of demanding devices, such as lifting the load, elevators, printing and packaging, printing and dyeing, materials Take-up and other general occasions. ■ high level of driving performance ● sensorless vector control mode has a unique, in the case without the use of the encoder can make various Kind of mechanical equipment operation in the precision of ultra-low region. With torque control mode, and can use the speed control mode, the torque limit function. ● with vector control (with encoder), the drive can achieve the position control and fast response, high-precision speed Control (zero-speed control, servo lock) and torque control. - [FR-A740 series, 3-phase 380V 50Hz grade, high performance vector control type] FR-A740-0.4K-the CHT 0.75 2.3A 0.75 2.1A 0.4 1.5A 0.2 0.8A FR-A740-0.75K-the CHT 1.5 3.8A 1.5 3.5A 0.75 2.5A 0.4 1.5A FR-A740-1.5K-the CHT 2.2 5.2A 2.2 4.8A 1.5 4A 0.75 2.5A FR-A740-2.2K-the CHT 3.7 8.3A 3.7 7.6A 2.2 6A 1.5 4A FR-A740-3.7K-CHT 5.5 12.6A 5.5 11.5A 3.7 9A 2.2 6A FR-A740-5.5K-the CHT 7.5 17A 7.5 16A 5.5 12A 3.7 9A FR-A740-7.5K-the CHT 11 25A 11 23A 7.5 17A 5.5 12A FR-A740-11K-the CHT 15 31A 15 29A 11 23A 7.5 17A FR-A740-15K-the CHT 18.5 38A 18.5 35A 15 31A 11 23A FR-A740-18.5K-CHT 22 47A 22 43A 18.5 38A 15 31A FR-A740-22-karat-the CHT 30 62A 30 57A 22 44A 18.5 38A FR-A740-30K-the CHT 37 77A 37 70A 30 57A 22 44A FR-A740-37K-the CHT 45 93A 45 85A 37 71A 30 57A FR-A740-45K-the CHT 55 116A 55 106A 45 86A 37 71A FR-A740-55K-the CHT NA NA 55 110A 45 86A FR-A740-75K-the CHT 110 216A 90 180A 75 144A 55 110A FR-A740-90K-the CHT 132 260A 110 216A 90 180A 75 144A FR-A740-110K-the CHT 160 325A 132 260A 110 216A 90 180A FR-A740-132K-CHT 185 361A 160 325A 132 260A 110 216A FR-A740-160K-CHT 220 432A 185 361A 160 325A 132 260A FR-A740-185K-CHT 250 481A 220 432A 185 361A 160 325A FR-A740-220K-CHT 280 547A 250 481A 220 432A 185 361A FR-A740-250K-the CHT 315 610A 280 547A 250 481A 220 432A FR-A740-280K-CHT 355 683A 315 610A 280 547A 250 481A FR-A740-315K-CHT 400 770A 355 683A 315 610A 280 547A FR-A740-355K-CHT 450 866A 400 770A 355 683A 315 610A FR-A740-400K-CHT 500 962A 450 866A 400 770A 355 683A FR-A740-450K-CHT 560 1094A 500 962A 450 866A 400 770A FR-A740-500K-CHT 630 1212A 560 1094A 500 962A 450 866A F700 products used in many common situations, especially for fans, pumps, air conditioning industry. ■ advanced feature-rich ● In addition to the other inverter conventional PID control functions, the expansion of multi-pump control functions. ■ Concerned about energy-efficient products ● optimal excitation control function, in addition to constant speed when you can use, in the acceleration and deceleration can also play a role, you can Further optimization of the energy saving effect. ● The newly developed energy-saving monitoring functions, through the operation panel, the output terminal (terminal CA / AM) and communications to Confirm the energy savings, energy-saving effect at a glance. - [FR-F740 series, 3-phase 380V 50Hz rating, energy saving Universal] - FR-F740-0.75K-the CHT [] 0.75 2.3A 0.75 2.1A FR-F740-1.5K-the CHT [] 1.5 3.8A 1.5 3.5A FR-F740-2.2K-the CHT [] 2.2 5.2A 2.2 4.8A FR-F740-3.7K-the CHT [] 3.7 8.3A 3.7 7.6A FR-F740-5.5K-CHT [] 5.5 12.6A 5.5 11.5A FR-F740-7.5K-the CHT [] 7.5 17A 7.5 16A FR-F740-11K-the CHT [] 11 25A 11 23A FR-F740-15K-the CHT [] 15 31A 15 29A FR-F740-18.5K-CHT [] 18.5 38A 18.5 35A FR-F740-22-karat-the CHT [] 22 47A 22 43A FR-F740-30K-the CHT [] 30 62A 30 57A FR-F740-37K-the CHT [] 37 77A 37 70A FR-F740-45K-the CHT [] 45 93A 45 85A FR-F740-55K-the CHT [] 55 116A 55 106A FR-F740-S75K-CHT 75 144A NA FR-F740-S90K-CHT 90 180A 75 144A FR-F740-S110K-CHT 110 216A 90 180A FR-F740-S132K-CHT 132 260A 110 216A FR-F740-S160K-CHT 160 325A 132 260A FR-F740-S185K-CHT 185 361A 160 325A FR-F740-S220K-CHT 220 432A 185 361A FR-F740-S250K-CHT 250 481A 220 432A FR-F740-S280K-CHT 280 547A 250 481A FR-F740-S315K-CHT 315 610A 280 547A FR-F740-S355K-CHT 355 683A 315 610A FR-F740-S400K-CHT 400 770A 355 683A FR-F740-S450K-CHT 450 866A 400 770A FR-F740-S500K-CHT 500 962A 450 866A FR-F740-S560K-CHT 560 1094A 500 962A FR-F740-S630K-CHT 630 1212A 560 1094A E700 products for the economy to achieve high driving performance products ■ improve drive performance ● With flux vector control mode: the 0.5HZ case, the use of advanced magnetic flux vector control mode Torque increased to 200% (a 3.7KW below) ● short-time overload increased to 200% allowed to continue for the 3S, false alarms will be less to occur, an improved limit torque The current limit function can provide the necessary protection for mechanical. - [FR-E740 series, 3-phase 380V 50HZ grade, lightweight general-purpose (150% 60 seconds of overload)] - FR-E740-0.4K-the CHT 0.4KW 1.6A FR-E740-0.75K-the CHT 0.75KW 2.6A FR-E740-1.5K-the CHT 1.5KW 4.0A FR-E740-2.2K-the CHT 2.2KW 6.0A FR-E740-3.7K-the CHT 3.7KW 9.5A FR-E740-5.5K-the CHT 5.5KW 12A FR-E740-7.5K-the CHT 7.5KW 17A FR-E740-11K-the CHT 11KW 23A FR-E740-15K-the CHT 15KW 30A D700 product of a multi-functional, compact products ■ multi-function products ● a general-purpose flux vector control mode: in 1HZ situation, so that torque increased to 150% expansion of the floating roller control And the triangular wave function. ● with safety stop functions: emergency stop in two ways: by controlling the MC contactors to cut off the input power Inverter module drive circuit inside the inverter direct cut to conform to European standards of safety function, the purpose of Is to save the equipment investment. - [FR-D740 series, 3-phase 380V 50HZ Level, Compact (60 seconds 150% overload)] - FR-D740-0.4K-the CHT 0.4KW 1.2A FR-D740-0.75K-the CHT 0.75KW 2.2A FR-D740-1.5K-the CHT 1.5KW 3.6A FR-D740-2.2K-the CHT 2.2KW 5.0A FR-D740-3.7K-the CHT 3.7KW 8.0A FR-D740-5.5K-the CHT 5.5KW from 12.0 A up FR-D740-7.5K-CHT 7.5KW 16.0A |
Admin>>>
You are the 8618 visitor
Copyright © GuangDong ICP No. 10089450, Upper Haiheng enjoy Automation Technology Co., Ltd. (Fuzhou Office) All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 8618 visitor
Copyright © GuangDong ICP No. 10089450, Upper Haiheng enjoy Automation Technology Co., Ltd. (Fuzhou Office) All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility